WTT User's Guide | ||
---|---|---|
Previous | Boiling Point | Next |
ln(p/p°) = a1 + a2/T + a3×ln(T) + a4×T + a5×T2 + a6/T2 + a7×T6 + a8/T4
where p° = 1 kPa
The basis for this functional form is discussed in [1].
Please note that the equations described above are expressed in terms of vapor pressure and not in the necessary inverted form. The parameters for a given fit can be found in the model summary for the associated phase boundary pressure contour.
Previous | Home | Next |
Wagner25 | Up | REFPROP |
©2012 copyright by the US Secretary of Commerce on
behalf of the United States of America. All rights reserved.
Privacy Policy/Security Notice/Accessibility Statement/Disclaimer/Freedom of Information Act (FOIA)
The TRC Group is part of the Thermophysical Properties Division in NIST's Material Measurement Laboratory