Compound Information 

Name: 3,6-dioxa-1-decanol
Formula: C8H18O3
Molar Mass: 162.229
Additional Names: butoxyethoxyethanol
butyl diglycol
butyl digol
butyl dioxitol
dowanol DB
ethanol, 2-(2-butoxyethoxy)-
O-butyl diethylene glycol
diethylene glycol, n-butyl ether
ethanol, 2,2'-oxybis-, monobutyl ether
diethylene glycol monobutyl ether
butyl oxitol glycol ether
butadigol
butyl carbitol
2-(2-butoxyethoxy)ethanol
diglycol monobutyl ether
diethylene glycol n-butyl ether
diethylene glycol mono-n-butyl ether
diethylene glycol butyl ether
Image of 3,6-dioxa-1-decanol

Please be patient while the web interface loads...

Property Availability 

For this compound, WTT contains critically evaluated recommendations for:
(Please note that if more than 50 points are used for regression, only the 50 most-constraining points are reported)

  • Normal boiling temperature (Liquid and Gas)
    • Critical temperature (Liquid and Gas)
      1 experimental data points
      • Critical pressure (Liquid and Gas)
        1 experimental data points
        • Boiling temperature (Liquid in equilibrium with Gas) as a function of Pressure
          Pressure from 0.0206909 kPa to 3143.44 kPa
          • Phase boundary pressure (Liquid in equilibrium with Gas) as a function of Temperature
            Temperature from 298 K to 692.3 K
            44 experimental data points
            • Critical density (Liquid and Gas)
              • Density
                • Density (Liquid in equilibrium with Gas) as a function of Temperature
                  Temperature from 210 K to 692.3 K
                  41 experimental data points
                • Density (Liquid) as a function of Temperature and Pressure
                  Temperature from 283.15 K to 353.15 K
                  Pressure from 0.02 kPa to 25000 kPa
                  50 experimental data points
                • Density (Gas) as a function of Temperature and Pressure
                  Temperature from 340 K to 690 K
                  Pressure from 0.0005 kPa to 500 kPa
              • Heat capacity at saturation pressure (Liquid in equilibrium with Gas) as a function of Temperature
                Temperature from 250 K to 678.454 K
                1 experimental data points
                • Heat capacity at constant pressure (Ideal Gas) as a function of Temperature
                  Temperature from 200 K to 1000 K
                  • Enthalpy
                    • Enthalpy (Liquid in equilibrium with Gas) as a function of Temperature
                      Temperature from 250 K to 678.454 K
                    • Enthalpy (Ideal Gas) as a function of Temperature
                      Temperature from 200 K to 1000 K
                  • Entropy (Ideal Gas) as a function of Temperature and Pressure
                    Temperature from 200 K to 1000 K
                    • Speed of sound (Liquid) as a function of Temperature and Pressure
                      Temperature from 293.15 K to 303.15 K
                      Pressure from 3e-08 kPa to 0.0292984 kPa
                      20 experimental data points
                      • Refractive index (Liquid) as a function of Wavelength, Temperature, and Pressure
                        Temperature from 283.15 K to 566.332 K
                        19 experimental data points
                        • Surface tension (Liquid in equilibrium with Gas) as a function of Temperature
                          Temperature from 297.995 K to 317.988 K
                          6 experimental data points
                          • Viscosity
                            • Viscosity (Gas) as a function of Temperature and Pressure
                              Temperature from 510 K to 1030 K
                            • Viscosity (Liquid in equilibrium with Gas) as a function of Temperature
                              Temperature from 283.15 K to 690 K
                              12 experimental data points
                          • Thermal conductivity
                            • Thermal conductivity (Gas) as a function of Temperature and Pressure
                              Temperature from 510 K to 1030 K
                            • Thermal conductivity (Liquid in equilibrium with Gas) as a function of Temperature
                              Temperature from 200 K to 620 K
                              8 experimental data points
                          • Enthalpy of formation
                            • Enthalpy of formation (Gas)
                            • Enthalpy of formation (Liquid)

                          About WTT 

                          NIST/TRC Web Thermo Tables (WTT)
                          NIST Standard Reference Subscription Database 3 - Professional Edition
                          Version 2-2012-1-Pro

                          This web application provides access to a collection of critically evaluated thermodynamic property data for pure compounds with a primary focus on organics. These data were generated through dynamic data analysis, as implemented in the NIST ThermoData Engine software package [1, 2, 3, 4, 5, 6]. Some critically evaluated data from the historical TRC Thermodynamic Tables archive [7, 8] are included, also. As of May 2012, the Professional Edition contains information on 28432 compounds and total of 531486 evaluated data points. The properties covered by both versions (32 total) are described in Properties and Implemented Models.

                          Developed by Kenneth Kroenlein, Chris D. Muzny, Andrei F. Kazakov, Vladimir Diky, Robert D. Chirico, Joseph W. Magee, Ilmutdin Abdulagatov and Michael Frenkel.

                          Thermodynamics Research Center (TRC)
                          Thermophysical Properties Division
                          National Institute of Standards and Technology
                          Boulder CO 80305-3337

                          Questions and comments should be addressed to Dr. Michael Frenkel .

                          DISCLAIMER: The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high-quality copy of the database and to verify that the methods and data contained therein have been selected on the basis of sound scientific judgement. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the program and database.