Compound Information 

Name: di-n-octadecyl sebacate
Formula: C46H90O4
Molar Mass: 707.222
Image of di-n-octadecyl sebacate

Please be patient while the web interface loads...

Property Availability 

For this compound, WTT contains critically evaluated recommendations for:

  • Normal boiling temperature (Liquid and Gas)
    • Critical temperature (Liquid and Gas)
      • Critical pressure (Liquid and Gas)
        • Boiling temperature (Liquid in equilibrium with Gas) as a function of Pressure
          Pressure from 0.0013154 kPa to 347.544 kPa
          • Phase boundary pressure (Liquid in equilibrium with Gas) as a function of Temperature
            Temperature from 330 K to 1074 K
            • Critical density (Liquid and Gas)
              • Density
                • Density (Liquid in equilibrium with Gas) as a function of Temperature
                  Temperature from 330 K to 1074 K
                  4 experimental data points
                • Density (Gas) as a function of Temperature and Pressure
                  Temperature from 990 K to 1070 K
                  Pressure from 0.0001 kPa to 100 kPa
              • Heat capacity at saturation pressure (Liquid in equilibrium with Gas) as a function of Temperature
                Temperature from 250 K to 1052.52 K
                4 experimental data points
                • Heat capacity at constant pressure (Ideal Gas) as a function of Temperature
                  Temperature from 200 K to 1000 K
                  • Enthalpy
                    • Enthalpy (Liquid in equilibrium with Gas) as a function of Temperature
                      Temperature from 250 K to 1052.52 K
                    • Enthalpy (Ideal Gas) as a function of Temperature
                      Temperature from 200 K to 1000 K
                  • Viscosity
                    • Viscosity (Gas) as a function of Temperature and Pressure
                      Temperature from 880 K to 1610 K
                    • Viscosity (Liquid in equilibrium with Gas) as a function of Temperature
                      Temperature from 270 K to 1070 K
                  • Thermal conductivity
                    • Thermal conductivity (Gas) as a function of Temperature and Pressure
                      Temperature from 880 K to 1610 K
                    • Thermal conductivity (Liquid in equilibrium with Gas) as a function of Temperature
                      Temperature from 200 K to 960 K
                  • Enthalpy of formation
                    • Enthalpy of formation (Gas)
                    • Enthalpy of formation (Liquid)

                  About WTT 

                  NIST/TRC Web Thermo Tables (WTT)
                  NIST Standard Reference Subscription Database 3 - Professional Edition
                  Version 2-2012-1-Pro

                  This web application provides access to a collection of critically evaluated thermodynamic property data for pure compounds with a primary focus on organics. These data were generated through dynamic data analysis, as implemented in the NIST ThermoData Engine software package [1, 2, 3, 4, 5, 6]. Some critically evaluated data from the historical TRC Thermodynamic Tables archive [7, 8] are included, also. As of May 2012, the Professional Edition contains information on 28432 compounds and total of 531486 evaluated data points. The properties covered by both versions (32 total) are described in Properties and Implemented Models.

                  Developed by Kenneth Kroenlein, Chris D. Muzny, Andrei F. Kazakov, Vladimir Diky, Robert D. Chirico, Joseph W. Magee, Ilmutdin Abdulagatov and Michael Frenkel.

                  Thermodynamics Research Center (TRC)
                  Thermophysical Properties Division
                  National Institute of Standards and Technology
                  Boulder CO 80305-3337

                  Questions and comments should be addressed to Dr. Michael Frenkel .

                  DISCLAIMER: The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high-quality copy of the database and to verify that the methods and data contained therein have been selected on the basis of sound scientific judgement. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the program and database.